---
product_id: 256691942
title: "CPS Solenoid Valve Magnet Tool #TLMKC18 1-(Pack) CPS - TLMKC18 1"
brand: "cps"
price: "VT20192"
currency: VUV
in_stock: true
reviews_count: 5
category: "Cps"
url: https://www.desertcart.vu/products/256691942-cps-solenoid-valve-magnet-tool-tlmkc18-1-pack-cps-tlmkc18
store_origin: VU
region: Vanuatu
---

# Compatible with 2-, 3-, & 4-way valves 18mm industrial-grade magnet Durable ABS plastic housing CPS Solenoid Valve Magnet Tool #TLMKC18 1-(Pack) CPS - TLMKC18 1

**Brand:** cps
**Price:** VT20192
**Availability:** ✅ In Stock

## Summary

> 🧲 Unlock HVAC fixes instantly—because downtime is so last season!

## Quick Answers

- **What is this?** CPS Solenoid Valve Magnet Tool #TLMKC18 1-(Pack) CPS - TLMKC18 1 by cps
- **How much does it cost?** VT20192 with free shipping
- **Is it available?** Yes, in stock and ready to ship
- **Where can I buy it?** [www.desertcart.vu](https://www.desertcart.vu/products/256691942-cps-solenoid-valve-magnet-tool-tlmkc18-1-pack-cps-tlmkc18)

## Best For

- cps enthusiasts

## Why This Product

- Trusted cps brand quality
- Free international shipping included
- Worldwide delivery with tracking
- 15-day hassle-free returns

## Key Features

- • **Compact & Lightweight:** At just 45g and 2.54cm³, it’s the must-have tool for every HVAC professional’s kit.
- • **Robust Industrial Design:** Encased in durable ABS plastic for long-lasting use in demanding HVAC environments.
- • **Essential HVAC Emergency Tool:** Avoid costly service calls and hotel stays by restoring heat pump function on the spot.
- • **Universal Valve Compatibility:** Fits all common solenoid valves with a precise 18mm diameter for seamless troubleshooting.
- • **Instant Manual Valve Activation:** Magnetically lifts valve plunger to manually open solenoid valves—no power needed, no downtime.

## Overview

The CPS TLMKC18 Solenoid Valve Troubleshooting Magnet is a compact, industrial-grade tool designed to manually open solenoid valves by magnetically lifting their plunger. Compatible with 2-, 3-, and 4-way valves across all common brands, it fits an 18mm diameter valve stem and is housed in durable ABS plastic. This essential HVAC tool enables quick troubleshooting and temporary operation of heat pumps and other systems, helping professionals avoid costly delays and service calls.

## Description

CPS TLMKC18 Solenoid Valve Troubleshooting MagnetCPS TLMKC18 Solenoid Valve Troubleshooting Magnetx Direct connect or pilot operated 2-way solenoids 3- way reclaim valves 4-way reversing valves 0.75 (18 mm) fits all common industry valvesA must have tool that manually opens solenoid valves by lifting its stem and plunger using industrial grade magnet housed inside durable ABS plastic. Plunger Closed Position x Magnetically lifts plunger Manually opens solenoid valve for troubleshooting, temporary operation and/or maintenance of system Compatible with direct connected & pilot operated solenoid valves; 2 way solenoids, 3 way reclaim valves, 4 way reversing valves For use will all common solenoid brands Inner diameter of TLMKC18: 17mm Plunger Open with Magnet x

Review: All heat pumps have a reversing valve which is operated by a solenoid coil. Most heat pumps energize this coil to move a pilot valve to align the heat pump for cooling operation, a few heat pumps deenergize this coil to align the heat pump for cooling operations. Most HVAC technicians don't carry replacement coils around as there's too many different styles, however most carry this magnet. Last week when our heat pump gave us heat when we were trying to cool our house this magnet gave us cooling back. IF you're comfortable taking the power off your heat pump and removing the fan off the top of the outside unit you can remove the reversing valve coil and install this magnet. You know you've got the magnet orientation correct when you hear the pilot valve click as you slide the magnet onto the reversing valve. If you don't hear a click reverse the magnet and try again. If you still don't hear a click you need a new reversing valve as the pilot valve isn't changing position - that requires removing the freon in your heat pump and cutting the reversing valve out of the unit, replacing the reversing valve, and recharging the heat pump - that's beyond my skill set. But we've had AC from our heat pump for a week now using this magnet as I wait for a new reversing valve coil. Without this magnet we'd have had to check ourselves and pets into a nearby hotel while we waited, 7 days now. If you're the kind of person who can safely do common repairs to your heat pump - capacitors, motor changes, starter relay changes, etc then you need this magnet. If you're the kind of person that depends on a service call you need this magnet - your service man may not have one or more likely has there's installed on someone else's heat pump that's waiting on parts. $30 for this magnet vs. 7 days and counting in a nearby hotel room? I'll take the magnet please. And if you're one of those few whose heat pump reversing valve is energized for heat you may want this magnet to ensure you'll have heat from your heat pump vs from just the electric strip heaters in your indoor unit. Rheem/Ruud heat pumps are this configuration. If you're going to install this magnet yourself read and follow all the precautions in the manuals that came with your HVAC unit. There are lethal voltages present (240 vac) and rotating equipment hazards (those beefy fan blades on the outside unit). Work safely and if you're not sure if you can, call a technician.
Review: Zum testen von Magnetventielen für meine Bewässerung. TOP Produkt

## Features

- Solenoid Valve Troubleshooting Magnet, 18mm
- Direct connect or pilot operated 2-way solenoids
- 3- way reclaim valves
- 4-way reversing valves
- 0.75" (18 mm) fits all common industry valves

## Technical Specifications

| Specification | Value |
|---------------|-------|
| ASIN | B009M9UIHU |
| ASIN  | B009M9UIHU |
| Batteries Included? | No |
| Batteries Required? | No |
| Best Sellers Rank | #124,311 in Kitchen ( See Top 100 in Kitchen ) #1,067 in Refrigerator Magnets |
| Customer Reviews | 4.7 4.7 out of 5 stars (863) |
| Customer reviews | 4.7 4.7 out of 5 stars (863) |
| Date First Available | 3 August 2017 |
| Date First Available  | 3 August 2017 |
| Is Discontinued By Manufacturer  | No |
| Item Package Quantity | 1 |
| Item Weight | 45.4 g |
| Item model number | CPS - TLMKC18 |
| Item model number  | CPS - TLMKC18 |
| Manufacturer | CPS |
| Manufacturer  | CPS |
| Material | Plastic |
| Number Of Pieces | 1 |
| Part number | CPS - TLMKC18 |
| Power source type | corded-electric |
| Product Dimensions | 2.54 x 2.54 x 2.54 cm; 45.36 g |
| Product Dimensions  | 2.54 x 2.54 x 2.54 cm; 45.36 g |
| Size | 1 inch |
| Specification met | CE |

## Product Details

- **Brand:** CPS
- **Exterior finish:** ABS plastic
- **Inlet connection size:** 18 Millimeters
- **Item dimensions L x W x H:** 25 x 25 x 25 millimeters
- **Material:** Plastic

## Images

![CPS Solenoid Valve Magnet Tool #TLMKC18 1-(Pack) CPS - TLMKC18 1 - Image 1](https://m.media-amazon.com/images/I/51NrQGs+IwL.jpg)

## Questions & Answers

**Q: Can this be used on electronic expansion valves to open to flow nitrogen when brazing on the system?**
A: No, I tried this on a Daikin EEV and it did not open the valve. Rotating a conventional magnet around the valve did open it.
Former NATE certified HVAC mechanic

**Q: Will this work on the EEV's to open them when brazing on a system?**
A: No, for EEV's it is best to use an EEV magnet to open/close those valves. There are tricks, but this type of magnet will not work for this purpose.

**Q: Will this fit on the larger MKC2 solenoids?**
A: Yes it will!

**Q: How many magnets come with the order?**
A: One magnet. That’s just a picture showing what it looks like.

## Customer Reviews

### ⭐⭐⭐⭐⭐ Review
*by A***C on 13 August 2022*

All heat pumps have a reversing valve which is operated by a solenoid coil. Most heat pumps energize this coil to move a pilot valve to align the heat pump for cooling operation, a few heat pumps deenergize this coil to align the heat pump for cooling operations. Most HVAC technicians don't carry replacement coils around as there's too many different styles, however most carry this magnet. Last week when our heat pump gave us heat when we were trying to cool our house this magnet gave us cooling back. IF you're comfortable taking the power off your heat pump and removing the fan off the top of the outside unit you can remove the reversing valve coil and install this magnet. You know you've got the magnet orientation correct when you hear the pilot valve click as you slide the magnet onto the reversing valve. If you don't hear a click reverse the magnet and try again. If you still don't hear a click you need a new reversing valve as the pilot valve isn't changing position - that requires removing the freon in your heat pump and cutting the reversing valve out of the unit, replacing the reversing valve, and recharging the heat pump - that's beyond my skill set. But we've had AC from our heat pump for a week now using this magnet as I wait for a new reversing valve coil. Without this magnet we'd have had to check ourselves and pets into a nearby hotel while we waited, 7 days now. If you're the kind of person who can safely do common repairs to your heat pump - capacitors, motor changes, starter relay changes, etc then you need this magnet. If you're the kind of person that depends on a service call you need this magnet - your service man may not have one or more likely has there's installed on someone else's heat pump that's waiting on parts. $30 for this magnet vs. 7 days and counting in a nearby hotel room? I'll take the magnet please. And if you're one of those few whose heat pump reversing valve is energized for heat you may want this magnet to ensure you'll have heat from your heat pump vs from just the electric strip heaters in your indoor unit. Rheem/Ruud heat pumps are this configuration. If you're going to install this magnet yourself read and follow all the precautions in the manuals that came with your HVAC unit. There are lethal voltages present (240 vac) and rotating equipment hazards (those beefy fan blades on the outside unit). Work safely and if you're not sure if you can, call a technician.

### ⭐⭐⭐⭐⭐ Review
*by W***G on 16 July 2024*

Zum testen von Magnetventielen für meine Bewässerung. TOP Produkt

### ⭐⭐⭐⭐⭐ Review
*by I***L on 23 July 2024*

Me gustó mucho, muy buena calidad.

## Frequently Bought Together

- CPS Products TLMKC18 Solenoid Valve Magnet Tool, Original Version
- Rotation Tester and AC Detector for Circulating Pumps etc
- Solenoid Tester, Solenoid Magnet Tool to Detects Ac Fields, and Rotation Tester for Circulating Pumps

---

## Why Shop on Desertcart?

- 🛒 **Trusted by 1.3+ Million Shoppers** — Serving international shoppers since 2016
- 🌍 **Shop Globally** — Access 737+ million products across 21 categories
- 💰 **No Hidden Fees** — All customs, duties, and taxes included in the price
- 🔄 **15-Day Free Returns** — Hassle-free returns (30 days for PRO members)
- 🔒 **Secure Payments** — Trusted payment options with buyer protection
- ⭐ **TrustPilot Rated 4.5/5** — Based on 8,000+ happy customer reviews

**Shop now:** [https://www.desertcart.vu/products/256691942-cps-solenoid-valve-magnet-tool-tlmkc18-1-pack-cps-tlmkc18](https://www.desertcart.vu/products/256691942-cps-solenoid-valve-magnet-tool-tlmkc18-1-pack-cps-tlmkc18)

---

*Product available on Desertcart Vanuatu*
*Store origin: VU*
*Last updated: 2026-05-04*