Technical Specifications Function:Measurement of AC/DC current, leakage current Power Supply:Zn-Mn dry battery,6F22,9V, continuous use for 100h(not included) Test Mode:Clip-on CT, noncontact measurement Clamp Size:φ7mm Measurement Range:0mA~60.0A AC/DC Resolution:1mA AC/DC Accuracy:±2%rdg±5dgt (23℃±5℃, below 75%rh) Display Mode:Four digits LCD display Dimension: LWH: 168mm×65mm×34mm LCD Dimension:35mm×21.5mm; Display Domain: 32mm×15mm Sampling Rate:2 times/s Frequency:AC: 45Hz-400Hz Polarity Indication:DC current auto identified and display“—” Test Position:Tested wire in the jaw center Range Shift:Automatically Line Voltage:AC600V RS232 Interface:Data stored in the memory of the meter via RS232 upload to PC Com-Configure:Baud rate:9600, data bit:8, stop bit:1, check bit: NONE Data Memory:99units, FULL blinks when the memory is full Reading Hold:DH indicating the reading is hold Out of Range:OL indicating the current is out of range Auto Power-off:5 Minutes after power on, it will power off automatically to lower the power consumption Battery Voltage:Indicating the battery voltage is lower than 7.2V.Then the battery have to be changed Weight:180g(including the battery) Working Current:10mA Humiture:-10℃-50℃,below 80%rh Limit Temperature Error:-10℃-0℃ and 40℃-50℃, within 2%rdg Humiture Storage:-10℃-60℃,below 70%rh Insulating Strength:AC 3700V/rms. (between the alloy of the clamp and the housing) Applicable safety rules:IEC1010-1, IEC1010-2-032, pollution:2, CAT Ⅲ(600V) Packing Size: (L ×W ×H): 220×110 ×75(mm) Weight: 0.3Kg